Advanced manufacturing, validated assembly, and customized designs for regulated combination products
Jecture combines advanced manufacturing, precision grinding, and validated assembly processes to deliver stable, reproducible cannula performance for regulated combination products in accordance with ISO 7864 and ISO 9626.
Our technologies ensure consistent geometry, controlled surface quality, and reliable performance – helping partners meet regulatory requirements and deliver trusted healthcare solutions worldwide.
Directly to:
Standard Range & Customization | Add-ons / Material & Process Options | QUINTUM Needle™ | Quality commitment
Cannula Design
Precision-engineered cannula tip geometries
Back Bevel / Trocar
Market Area
Vascular Access & Infusion Systems - Diagnostics & Sampling Systems
Huber Tip
Market Area
Vascular Access & Infusion Systems - Specialized Medical Applications
Please contact us regarding your suitable cannula design
Our experts will be happy to assist you with practical examples and real-world experience.
Standard Range & Customization
Jecture delivers more than standard cannulas – we provide customized tip geometries, dimensions, and wall types to meet the specific needs of your application.
- Diameter: 3G (Ø 6.7 mm) – 34G (Ø 0.18 mm)
- Length: 5 mm – 150 mm
- Wall Types: Regular, Thin, Extra Thin, Ultra Thin
- Custom dimensions available - tailored for specific applications with precise tolerances
Add-ons / Material & Process Options
Material Variants
Cannula Lengths
Total length tolerances
Surface Treatments
Special Modifications
Customized Solutions
Precision Manufacturing Capabilities
- CNC & ECG/ECC grinding for precise tip geometries
- Anti-coring treatment for clean penetration
- Surface finishing and electropolishing for consistent smoothness
- Predictable performance verified via functional testing
QUINTUM Needle™ – The 5-Bevel Standard for Secure Injection Systems
The QUINTUM Needle™ combines tissue-friendly penetration with medtech-controlled manufacturing. Validated for approved combination products, it is reliably produced in the billions, ensuring stability and dependability at the point of care.
Technology & Design
The QUINTUM Needle™ tip integrates a tissue-friendly point with a robust back-bevel to provide precise penetration and consistent injection force. Geometry, anti-coring features, and siliconization are controlled across the full product lifecycle, ensuring patient-interface precision.
The design allows automated assembly without damaging elastomer components and guarantees mechanical stability during handling and system integration.
“Jecture delivers 5-Bevel cannula systems not as an innovation – but as a stable standard for billions of injections.”
Gentle penetration
Consistent injection force
Clean penetration
Tier-1 validated
Lifecycle stability
Audit-proven & pharma-aligned
Optimized for medtech serial production
The Jecture quality commitment
At Jecture, quality means consistently delivering cannula solutions that meet defined application, performance, and regulatory requirements — from application-specific engineering and controlled manufacturing processes to validation, inspection, and reliable serial production.
Surface Treatments & Patient Interface Control
Controlled surface and geometry processes are essential for reliable cannula function, product cleanliness, and patient comfort.
- Sandblasting
- Laser marking
- Notching
- Siliconization
- Radius treatment and edge rounding
- Chamfering and controlled bevels
- Polishing
- Anti-coring processes
Together, these processes support controlled penetration forces, consistent surface quality, and high cleanliness standards.
Validation & Performance Assurance
Our ISO 13485-certified quality management system and controlled processes provide the foundation for reproducible cannula performance throughout serial production.
- Validation within global Tier-1 customer programs
- Controlled and documented manufacturing processes
- Reproducible performance in high-volume serial production
- Consistent function at the patient interface
- Controlled insertion forces and fluid delivery
This provides reliable and consistent performance across defined applications and production volumes.
Performance & Customer Value
Application-specific design and integration expertise translate technical quality into measurable customer value.
- Stable and reproducible cannula performance
- Application-specific geometries and surface properties
- Regulatory-aligned solutions for combination products
- Integration-ready designs for prefilled syringes, auto-injectors, and other drug delivery systems
- 100% final inspection of defined critical characteristics
The result is an application-specific cannula solution aligned with device, quality, and regulatory requirements.
Success starts with an Inquiry!
Please contact us for your suitable cannula solution
Our experts in bespoke cannula solutions or our combination product range
will respond to your enquiry.
European market
Danica Spahn
Group Key Account Manager
American market + RoW
Donny Browning
Group Key Account Manager